<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dreiphasiger String-Wechselrichter - Inverter.at</title>
	<atom:link href="https://inverter.at/product-category/wechselrichter/dreiphasiger-string-wechselrichter/feed/" rel="self" type="application/rss+xml" />
	<link>https://inverter.at</link>
	<description></description>
	<lastBuildDate>Mon, 12 Oct 2026 21:32:51 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://inverter.at/wp-content/uploads/2026/10/cropped-cropped-deye_icon-32x32.png</url>
	<title>Dreiphasiger String-Wechselrichter - Inverter.at</title>
	<link>https://inverter.at</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SUN-100/125K-SG02HP3-EU-GM8/GM10</title>
		<link>https://inverter.at/product/sun-100-125k-sg02hp3-eu-gm8-gm10/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:46 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=679</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-8K-SG01HP3-EU-AM2</title>
		<link>https://inverter.at/product/sun-8k-sg01hp3-eu-am2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=669</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-10K-SG01HP3-EU-DM2</title>
		<link>https://inverter.at/product/sun-10k-sg01hp3-eu-dm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=670</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-12K-SG01HP3-EU-AM2</title>
		<link>https://inverter.at/product/sun-12k-sg01hp3-eu-am2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=671</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-15K-SG01HP3-EU-AM2</title>
		<link>https://inverter.at/product/sun-15k-sg01hp3-eu-am2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=672</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-20K-SG01HP3-EU-AM2</title>
		<link>https://inverter.at/product/sun-20k-sg01hp3-eu-am2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=673</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-25K-SG01HP3-EU-AM2</title>
		<link>https://inverter.at/product/sun-25k-sg01hp3-eu-am2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=674</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-29.9K-SG02HP3-EU-BM4</title>
		<link>https://inverter.at/product/sun-29-9k-sg02hp3-eu-bm4/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=675</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>&quot;SUN-30K-SG02HP3-EU-BM4</title>
		<link>https://inverter.at/product/sun-30k-sg02hp3-eu-bm4/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=676</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-50K-SG02HP3-EU-BM4</title>
		<link>https://inverter.at/product/sun-50k-sg02hp3-eu-bm4/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=677</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100 % unsymmetrischer Ausgang, jede Phase</div></li>
 	<li>
<div>Wechselstrom-Paar zur Nachrüstung bestehender</div>
<div>Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (Grid-gebundene/off-Grid-modus)</div>
<div>Unterstützt die parallele Verbindung mehrerer Batterien</div></li>
 	<li>
<div>Max. Lade-/Entladestrom von 50A</div></li>
 	<li>
<div>Hochspannungsbatterie, höhere Effizienz</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung</div>
<div>aus Dieselgenerator</div></li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="273">Modell</td>
<td width="100">SUN-5K -SG01HP3-EU-AM2</td>
<td width="100">SUN-6K -SG01HP3-EU-AM2</td>
<td width="100">SUN-8K -SG01HP3-EU-AM2</td>
<td width="100">SUN-10K -SG01HP3-EU-AM2</td>
<td width="100">SUN-12K -SG01HP3-EU-AM2</td>
<td width="100">SUN-15K -SG01HP3-EU-AM2</td>
<td width="100">SUN-20K -SG01HP3-EU-AM2</td>
<td width="100">SUN-25K -SG01HP3-EU-AM2</td>
</tr>
<tr>
<td width="273">Batterieeingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Batterie-Typ</td>
<td colspan="8" width="800">Li-lon</td>
</tr>
<tr>
<td width="273">Batteriespannungsbereich (V)</td>
<td colspan="8" width="800">160-700</td>
</tr>
<tr>
<td width="273">Max. Ladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Max. Entladestrom (A)</td>
<td width="100">30</td>
<td width="100">30</td>
<td colspan="5" width="500">37</td>
<td width="100">50</td>
</tr>
<tr>
<td width="273">Ladestrategie für Li-Ionen-Akkus</td>
<td colspan="8" width="800">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="273">Anzahl der Batterieeingänge</td>
<td colspan="8" width="800">1</td>
</tr>
<tr>
<td width="273">PV-String-Eingangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
<td>30000</td>
<td>40000</td>
<td>50000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsleistung (W)</td>
<td width="100">8000</td>
<td width="100">9600</td>
<td width="100">12800</td>
<td width="100">16000</td>
<td width="100">19200</td>
<td width="100">24000</td>
<td width="100">32000</td>
<td width="100">40000</td>
</tr>
<tr>
<td width="273">Max. DC-Eingangsspannung (V)</td>
<td colspan="8" width="800">1000</td>
</tr>
<tr>
<td width="273">Startspannung (V)</td>
<td colspan="8" width="800">180</td>
</tr>
<tr>
<td width="273">MPPT-Spannungsbereich (V)</td>
<td colspan="8" width="800">150-800</td>
</tr>
<tr>
<td width="273">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="700">600</td>
<td width="100">700</td>
</tr>
<tr>
<td width="273">Max. Eingangskurzschlussstrom (A)</td>
<td colspan="4" width="400">30+30</td>
<td colspan="2" width="200">39+30</td>
<td colspan="2" width="200">39+39</td>
</tr>
<tr>
<td width="273">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="4" width="400">20+20</td>
<td colspan="2" width="200">26+20</td>
<td colspan="2" width="200">26+26</td>
</tr>
<tr>
<td width="273">Anzahl der MPP-Tracker/Anzahl der Strings  MPP-Tracker</td>
<td colspan="4" width="400">2/1+1</td>
<td colspan="2" width="200">2/2+1</td>
<td colspan="2" width="200">2/2+2</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsdaten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Nenn-AC-Eingangs-/Ausgangswirkleistung (W)</td>
<td width="100">5000</td>
<td width="100">6000</td>
<td width="100">8000</td>
<td width="100">10000</td>
<td width="100">12000</td>
<td width="100">15000</td>
<td width="100">20000</td>
<td width="100">25000</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangs-Scheinleistung (VA)</td>
<td width="100">5500</td>
<td width="100">6600</td>
<td width="100">8800</td>
<td width="100">11000</td>
<td width="100">13200</td>
<td width="100">16500</td>
<td width="100">22000</td>
<td width="100">27500</td>
</tr>
<tr>
<td width="273">
<div>Spitzenleistung (ohne Netz)</div>
</td>
<td colspan="8" width="800">1.5,fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="273">AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">7,6/7,3</td>
<td width="100">9,1/8,7</td>
<td width="100">12.2/11.6</td>
<td width="100">15.2/14.5</td>
<td width="100">18.2/17.4</td>
<td width="100">22.8/21.8</td>
<td width="100">30.4/29</td>
<td width="100">37,9/36,3</td>
</tr>
<tr>
<td width="273">Max. AC-Eingangs-/Ausgangsstrom (A)</td>
<td width="100">8,4/8</td>
<td width="100">10/9.6</td>
<td width="100">13.4/12.8</td>
<td width="100">16.7/16</td>
<td width="100">20/19.2</td>
<td width="100">25/24</td>
<td width="100">33.4/31.9</td>
<td width="100">41,7/39,9</td>
</tr>
<tr>
<td width="273">Max. kontinuierlicher AC-Durchgang (Netz zum Laden) (A)</td>
<td colspan="4" width="400">40</td>
<td colspan="4" width="400">80</td>
</tr>
<tr>
<td width="273">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="8" width="800">220/380 V, 230/400 V 0,85 Un-1,1 Un</td>
</tr>
<tr>
<td width="273">
<div>Form des Netzanschlusses</div>
</td>
<td colspan="8" width="800">3L+N+PE</td>
</tr>
<tr>
<td width="273">
<div>Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</div>
</td>
<td colspan="8" width="800">50Hz/45Hz-55Hz  60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="273">Einstellbereich des Leistungsfaktors</td>
<td colspan="8" width="800">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="273">Gesamte harmonische Verzerrung des Stroms THDi</td>
<td colspan="8" width="800">&lt;3 % ( Nennleistung)</td>
</tr>
<tr>
<td width="273">
<div>DC-strom stromeinspeisung</div>
</td>
<td colspan="8" width="800">&lt;0,5 % ln</td>
</tr>
<tr>
<td width="273"><strong>Wirkungsgrad</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Max. Wirkungsgrad</td>
<td colspan="8" width="800">97,6 %</td>
</tr>
<tr>
<td width="273">Euro-Wirkungsgrad</td>
<td colspan="8" width="800">97,0 %</td>
</tr>
<tr>
<td width="273">MPPT-Wirkungsgrad</td>
<td colspan="8" width="800">&gt; 99 %</td>
</tr>
<tr>
<td width="273"><strong>Schutz der Geräte</strong></td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Integriert</td>
<td colspan="8" width="800">
<div>DC Polarity Reverse Connection Protection, AC Output Überstromschutz, Wärmeschutz, AC Output</div>
<div>Überspannungsschutz, AC Output Kurzschlussschutz, DC Component Monitoring, Überspannungs-Lastfallschutz,</div>
<div>Erdungsfehler-Stromüberwachung, Lichtbogen-Fehler-Stromunterbrecher (optional), Netzüberwachung,</div>
<div>Inselschutz-Überwachung, Erdfehler-Erkennung, DC-Eingangsschalter,Gleichstrom-Isolations</div>
<div>Impedanz-Überwachung, Rückstrom-Erkennung (RCD), Überspannungsschutz-Niveau</div>
</td>
</tr>
<tr>
<td width="273">Überspannungsschutzstufe</td>
<td colspan="8" width="800">TYP II (DC), TYP II (AC)</td>
</tr>
<tr>
<td width="273">Schnittstelle</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td>LCD/LED-Anzeige</td>
<td colspan="8">LCD</td>
</tr>
<tr>
<td width="273">Kommunikationsinterface</td>
<td colspan="8" width="800">WIFI, RS485, CAN</td>
</tr>
<tr>
<td>
<div>Monitormodus</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN (optional)</div>
</td>
</tr>
<tr>
<td width="273">Allgemeine Daten</td>
<td colspan="8" width="800"></td>
</tr>
<tr>
<td width="273">Betriebstemperaturbereich</td>
<td colspan="8" width="800">-40 to +60℃, &gt;45℃ Leistungsminderung</td>
</tr>
<tr>
<td width="273">Zulässige Luftfeuchtigkeit</td>
<td colspan="8" width="800">0-100 %</td>
</tr>
<tr>
<td width="273">Zulässige Höhe</td>
<td colspan="8" width="800">2000m</td>
</tr>
<tr>
<td width="273">Lärm</td>
<td colspan="8" width="800">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="273">Schutzart (IP)</td>
<td colspan="8" width="800">IP 65</td>
</tr>
<tr>
<td width="273">Wechselrichtertopologie</td>
<td colspan="8" width="800">Nicht isoliert</td>
</tr>
<tr>
<td width="273">Überspannungskategorie</td>
<td colspan="8" width="800">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="273">Abmessung (BxHxT mm)</td>
<td colspan="8" width="800">408*638*237 (ohne Anschlüsse und Halterungen)</td>
</tr>
<tr>
<td width="273">Gewicht (kg]</td>
<td colspan="8" width="800">30.5</td>
</tr>
<tr>
<td width="273">Garantie</td>
<td colspan="8" width="800">
<div>5 Jahre/10 Jahre</div>
<div>Die Garantiezeit hängt vom endgültigen Installationsort des Wechselrichters ab. Weitere Informationen</div>
<div>finden Sie in der Garantierichtlinie</div>
</td>
</tr>
<tr>
<td width="273">Kühlmodus</td>
<td colspan="2" width="200">Natürliche Kühlung</td>
<td colspan="6" width="600">Intelligente Luftkühlung</td>
</tr>
<tr>
<td width="273">Netzregulierung</td>
<td colspan="8" width="800">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="273">Sicherheit EMV/Standard</td>
<td colspan="8" width="800">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>