<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dreiphasen-String-Wechselrichter (LV) - Inverter.at</title>
	<atom:link href="https://inverter.at/product-category/wechselrichter/dreiphasen-string-wechselrichter-lv/feed/" rel="self" type="application/rss+xml" />
	<link>https://inverter.at</link>
	<description></description>
	<lastBuildDate>Mon, 12 Oct 2026 21:32:51 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://inverter.at/wp-content/uploads/2026/10/cropped-cropped-deye_icon-32x32.png</url>
	<title>Dreiphasen-String-Wechselrichter (LV) - Inverter.at</title>
	<link>https://inverter.at</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SUN-80K-SG02HP3-EU-BM6</title>
		<link>https://inverter.at/product/sun-80k-sg02hp3-eu-bm6/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:46 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=678</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-3K-SG06LP1-EU-BM2</title>
		<link>https://inverter.at/product/sun-3k-sg06lp1-eu-bm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=664</guid>

					<description><![CDATA[<ul>
 	<li>48V low voltage battery, transformer isolation design</li>
 	<li>AC couple to retrofit existing solar system</li>
 	<li>Max. 10 pcs parallel for on-grid and off-grid operation; support multiple batteries parallel</li>
 	<li>6 time periods for battery charging/discharging</li>
 	<li>Max. charging/discharging current of 190A</li>
 	<li>Support storing energy from diesel generator</li>
 	<li>100% unbalanced output, max. output up to 50% rated power for each phase</li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Model</td>
<td width="120">SUN-3K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-4K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-5K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-6K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-8K-SG06<br />
LP3-EU-BM2</td>
</tr>
<tr>
<td width="304">Battery Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Battery Type</td>
<td colspan="5" width="840">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="304">Battery Voltage Range (V)</td>
<td colspan="5" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Charging/Discharging Current (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
</tr>
<tr>
<td width="304">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="840">Self-adaption to BMS</td>
</tr>
<tr>
<td width="304">Number of Battery Input</td>
<td colspan="5" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
</tr>
<tr>
<td width="304">Max. PV Input Power (W)</td>
<td width="120">4800</td>
<td width="120">6400</td>
<td width="120">8000</td>
<td width="120">9600</td>
<td width="120">12800</td>
</tr>
<tr>
<td width="304">Max. PV Input Voltage (V)</td>
<td colspan="5" width="840">800</td>
</tr>
<tr>
<td width="304">Start-up Voltage (V)</td>
<td colspan="5" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT Voltage Range (V)</td>
<td colspan="5" width="840">200-650</td>
</tr>
<tr>
<td width="304">Rated PV Input Voltage (V)</td>
<td colspan="5" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="840">20+20</td>
</tr>
<tr>
<td width="304">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="840">30+30</td>
</tr>
<tr>
<td width="304">No. of MPP Trackers/No. of Strings MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
</tr>
<tr>
<td width="304">AC Input/Output Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Active Power (W)</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Apparent Power (VA)</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Current (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Current (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
</tr>
<tr>
<td width="304">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="840">45</td>
</tr>
<tr>
<td width="304">Peak Power (off-grid) (W)</td>
<td colspan="5" width="840">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="304">Power Factor Adjustment Range</td>
<td colspan="5" width="840">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="304">Rated Input/Output Voltage</td>
<td colspan="5" width="840">220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE</td>
</tr>
<tr>
<td width="304">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="840">&lt;3% (of nominal power)</td>
</tr>
<tr>
<td width="304">DC Injection Current</td>
<td colspan="5" width="840">&lt;0.5% In</td>
</tr>
<tr>
<td colspan="6" width="1144">Eﬃciency</td>
</tr>
<tr>
<td width="304">Max. Efﬁciency</td>
<td colspan="5" width="840">97.6%</td>
</tr>
<tr>
<td width="304">Euro Efﬁciency</td>
<td colspan="5" width="840">97.0%</td>
</tr>
<tr>
<td width="304">MPPT Efﬁciency</td>
<td colspan="5" width="840">&gt;99%</td>
</tr>
<tr>
<td colspan="6" width="1144">Equipment Protection</td>
</tr>
<tr>
<td width="304">Integrated</td>
<td colspan="5" width="840">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</div>
</td>
</tr>
<tr>
<td width="304">Surge Protection Level</td>
<td colspan="5" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td colspan="6" width="1144">Interface</td>
</tr>
<tr>
<td width="304">LCD/LED Display</td>
<td colspan="5" width="840">LCD</td>
</tr>
<tr>
<td width="304">Communication Interface</td>
<td colspan="5" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td colspan="6" width="1144">General Data</td>
</tr>
<tr>
<td width="304">Operating Temperature Range (℃)</td>
<td colspan="5" width="840">-40 to +60℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="304">Permissible Ambient Humidity</td>
<td colspan="5" width="840">0-100%</td>
</tr>
<tr>
<td width="304">Permissible Altitude</td>
<td colspan="5" width="840">3000m</td>
</tr>
<tr>
<td width="304">Noise (dB)</td>
<td colspan="5" width="840">≤45</td>
</tr>
<tr>
<td width="304">Ingress Protection(IP) Rating</td>
<td colspan="5" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Inverter Topology</td>
<td colspan="5" width="840">Non-Isolated (solar), Isolated (battery)</td>
</tr>
<tr>
<td width="304">Over Voltage Category</td>
<td colspan="5" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="840">334×545×220 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="304">Weight (kg)</td>
<td colspan="4" width="840">20.8</td>
<td>21.9</td>
</tr>
<tr>
<td width="304">Type of Cooling</td>
<td colspan="5" width="840">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="304">Warranty</td>
<td colspan="5" width="840">5 Years/10 Years<br />
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="304">Grid Regulation</td>
<td colspan="5" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Safety / EMC Standard</td>
<td colspan="5" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-8K-SG06LP1-EU-BM3</title>
		<link>https://inverter.at/product/sun-8k-sg06lp1-eu-bm3/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=665</guid>

					<description><![CDATA[<ul>
 	<li>48V low voltage battery, transformer isolation design</li>
 	<li>AC couple to retrofit existing solar system</li>
 	<li>Max. 10 pcs parallel for on-grid and off-grid operation; support multiple batteries parallel</li>
 	<li>6 time periods for battery charging/discharging</li>
 	<li>Max. charging/discharging current of 190A</li>
 	<li>Support storing energy from diesel generator</li>
 	<li>100% unbalanced output, max. output up to 50% rated power for each phase</li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Model</td>
<td width="120">SUN-3K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-4K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-5K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-6K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-8K-SG06<br />
LP3-EU-BM2</td>
</tr>
<tr>
<td width="304">Battery Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Battery Type</td>
<td colspan="5" width="840">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="304">Battery Voltage Range (V)</td>
<td colspan="5" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Charging/Discharging Current (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
</tr>
<tr>
<td width="304">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="840">Self-adaption to BMS</td>
</tr>
<tr>
<td width="304">Number of Battery Input</td>
<td colspan="5" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
</tr>
<tr>
<td width="304">Max. PV Input Power (W)</td>
<td width="120">4800</td>
<td width="120">6400</td>
<td width="120">8000</td>
<td width="120">9600</td>
<td width="120">12800</td>
</tr>
<tr>
<td width="304">Max. PV Input Voltage (V)</td>
<td colspan="5" width="840">800</td>
</tr>
<tr>
<td width="304">Start-up Voltage (V)</td>
<td colspan="5" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT Voltage Range (V)</td>
<td colspan="5" width="840">200-650</td>
</tr>
<tr>
<td width="304">Rated PV Input Voltage (V)</td>
<td colspan="5" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="840">20+20</td>
</tr>
<tr>
<td width="304">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="840">30+30</td>
</tr>
<tr>
<td width="304">No. of MPP Trackers/No. of Strings MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
</tr>
<tr>
<td width="304">AC Input/Output Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Active Power (W)</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Apparent Power (VA)</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Current (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Current (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
</tr>
<tr>
<td width="304">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="840">45</td>
</tr>
<tr>
<td width="304">Peak Power (off-grid) (W)</td>
<td colspan="5" width="840">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="304">Power Factor Adjustment Range</td>
<td colspan="5" width="840">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="304">Rated Input/Output Voltage</td>
<td colspan="5" width="840">220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE</td>
</tr>
<tr>
<td width="304">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="840">&lt;3% (of nominal power)</td>
</tr>
<tr>
<td width="304">DC Injection Current</td>
<td colspan="5" width="840">&lt;0.5% In</td>
</tr>
<tr>
<td colspan="6" width="1144">Eﬃciency</td>
</tr>
<tr>
<td width="304">Max. Efﬁciency</td>
<td colspan="5" width="840">97.6%</td>
</tr>
<tr>
<td width="304">Euro Efﬁciency</td>
<td colspan="5" width="840">97.0%</td>
</tr>
<tr>
<td width="304">MPPT Efﬁciency</td>
<td colspan="5" width="840">&gt;99%</td>
</tr>
<tr>
<td colspan="6" width="1144">Equipment Protection</td>
</tr>
<tr>
<td width="304">Integrated</td>
<td colspan="5" width="840">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</div>
</td>
</tr>
<tr>
<td width="304">Surge Protection Level</td>
<td colspan="5" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td colspan="6" width="1144">Interface</td>
</tr>
<tr>
<td width="304">LCD/LED Display</td>
<td colspan="5" width="840">LCD</td>
</tr>
<tr>
<td width="304">Communication Interface</td>
<td colspan="5" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td colspan="6" width="1144">General Data</td>
</tr>
<tr>
<td width="304">Operating Temperature Range (℃)</td>
<td colspan="5" width="840">-40 to +60℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="304">Permissible Ambient Humidity</td>
<td colspan="5" width="840">0-100%</td>
</tr>
<tr>
<td width="304">Permissible Altitude</td>
<td colspan="5" width="840">3000m</td>
</tr>
<tr>
<td width="304">Noise (dB)</td>
<td colspan="5" width="840">≤45</td>
</tr>
<tr>
<td width="304">Ingress Protection(IP) Rating</td>
<td colspan="5" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Inverter Topology</td>
<td colspan="5" width="840">Non-Isolated (solar), Isolated (battery)</td>
</tr>
<tr>
<td width="304">Over Voltage Category</td>
<td colspan="5" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="840">334×545×220 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="304">Weight (kg)</td>
<td colspan="4" width="840">20.8</td>
<td>21.9</td>
</tr>
<tr>
<td width="304">Type of Cooling</td>
<td colspan="5" width="840">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="304">Warranty</td>
<td colspan="5" width="840">5 Years/10 Years<br />
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="304">Grid Regulation</td>
<td colspan="5" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Safety / EMC Standard</td>
<td colspan="5" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-4K-SG06LP3-EU</title>
		<link>https://inverter.at/product/sun-4k-sg06lp3-eu/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=666</guid>

					<description><![CDATA[<ul>
 	<li>48V low voltage battery, transformer isolation design</li>
 	<li>AC couple to retrofit existing solar system</li>
 	<li>Max. 10 pcs parallel for on-grid and off-grid operation; support multiple batteries parallel</li>
 	<li>6 time periods for battery charging/discharging</li>
 	<li>Max. charging/discharging current of 190A</li>
 	<li>Support storing energy from diesel generator</li>
 	<li>100% unbalanced output, max. output up to 50% rated power for each phase</li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Model</td>
<td width="120">SUN-3K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-4K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-5K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-6K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-8K-SG06<br />
LP3-EU-BM2</td>
</tr>
<tr>
<td width="304">Battery Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Battery Type</td>
<td colspan="5" width="840">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="304">Battery Voltage Range (V)</td>
<td colspan="5" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Charging/Discharging Current (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
</tr>
<tr>
<td width="304">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="840">Self-adaption to BMS</td>
</tr>
<tr>
<td width="304">Number of Battery Input</td>
<td colspan="5" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
</tr>
<tr>
<td width="304">Max. PV Input Power (W)</td>
<td width="120">4800</td>
<td width="120">6400</td>
<td width="120">8000</td>
<td width="120">9600</td>
<td width="120">12800</td>
</tr>
<tr>
<td width="304">Max. PV Input Voltage (V)</td>
<td colspan="5" width="840">800</td>
</tr>
<tr>
<td width="304">Start-up Voltage (V)</td>
<td colspan="5" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT Voltage Range (V)</td>
<td colspan="5" width="840">200-650</td>
</tr>
<tr>
<td width="304">Rated PV Input Voltage (V)</td>
<td colspan="5" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="840">20+20</td>
</tr>
<tr>
<td width="304">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="840">30+30</td>
</tr>
<tr>
<td width="304">No. of MPP Trackers/No. of Strings MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
</tr>
<tr>
<td width="304">AC Input/Output Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Active Power (W)</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Apparent Power (VA)</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Current (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Current (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
</tr>
<tr>
<td width="304">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="840">45</td>
</tr>
<tr>
<td width="304">Peak Power (off-grid) (W)</td>
<td colspan="5" width="840">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="304">Power Factor Adjustment Range</td>
<td colspan="5" width="840">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="304">Rated Input/Output Voltage</td>
<td colspan="5" width="840">220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE</td>
</tr>
<tr>
<td width="304">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="840">&lt;3% (of nominal power)</td>
</tr>
<tr>
<td width="304">DC Injection Current</td>
<td colspan="5" width="840">&lt;0.5% In</td>
</tr>
<tr>
<td colspan="6" width="1144">Eﬃciency</td>
</tr>
<tr>
<td width="304">Max. Efﬁciency</td>
<td colspan="5" width="840">97.6%</td>
</tr>
<tr>
<td width="304">Euro Efﬁciency</td>
<td colspan="5" width="840">97.0%</td>
</tr>
<tr>
<td width="304">MPPT Efﬁciency</td>
<td colspan="5" width="840">&gt;99%</td>
</tr>
<tr>
<td colspan="6" width="1144">Equipment Protection</td>
</tr>
<tr>
<td width="304">Integrated</td>
<td colspan="5" width="840">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</div>
</td>
</tr>
<tr>
<td width="304">Surge Protection Level</td>
<td colspan="5" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td colspan="6" width="1144">Interface</td>
</tr>
<tr>
<td width="304">LCD/LED Display</td>
<td colspan="5" width="840">LCD</td>
</tr>
<tr>
<td width="304">Communication Interface</td>
<td colspan="5" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td colspan="6" width="1144">General Data</td>
</tr>
<tr>
<td width="304">Operating Temperature Range (℃)</td>
<td colspan="5" width="840">-40 to +60℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="304">Permissible Ambient Humidity</td>
<td colspan="5" width="840">0-100%</td>
</tr>
<tr>
<td width="304">Permissible Altitude</td>
<td colspan="5" width="840">3000m</td>
</tr>
<tr>
<td width="304">Noise (dB)</td>
<td colspan="5" width="840">≤45</td>
</tr>
<tr>
<td width="304">Ingress Protection(IP) Rating</td>
<td colspan="5" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Inverter Topology</td>
<td colspan="5" width="840">Non-Isolated (solar), Isolated (battery)</td>
</tr>
<tr>
<td width="304">Over Voltage Category</td>
<td colspan="5" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="840">334×545×220 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="304">Weight (kg)</td>
<td colspan="4" width="840">20.8</td>
<td>21.9</td>
</tr>
<tr>
<td width="304">Type of Cooling</td>
<td colspan="5" width="840">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="304">Warranty</td>
<td colspan="5" width="840">5 Years/10 Years<br />
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="304">Grid Regulation</td>
<td colspan="5" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Safety / EMC Standard</td>
<td colspan="5" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-5K-SG06LP1-EU-BM2</title>
		<link>https://inverter.at/product/sun-5k-sg06lp1-eu-bm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=667</guid>

					<description><![CDATA[<ul>
 	<li>48V low voltage battery, transformer isolation design</li>
 	<li>AC couple to retrofit existing solar system</li>
 	<li>Max. 10 pcs parallel for on-grid and off-grid operation; support multiple batteries parallel</li>
 	<li>6 time periods for battery charging/discharging</li>
 	<li>Max. charging/discharging current of 190A</li>
 	<li>Support storing energy from diesel generator</li>
 	<li>100% unbalanced output, max. output up to 50% rated power for each phase</li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Model</td>
<td width="120">SUN-3K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-4K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-5K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-6K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-8K-SG06<br />
LP3-EU-BM2</td>
</tr>
<tr>
<td width="304">Battery Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Battery Type</td>
<td colspan="5" width="840">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="304">Battery Voltage Range (V)</td>
<td colspan="5" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Charging/Discharging Current (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
</tr>
<tr>
<td width="304">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="840">Self-adaption to BMS</td>
</tr>
<tr>
<td width="304">Number of Battery Input</td>
<td colspan="5" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
</tr>
<tr>
<td width="304">Max. PV Input Power (W)</td>
<td width="120">4800</td>
<td width="120">6400</td>
<td width="120">8000</td>
<td width="120">9600</td>
<td width="120">12800</td>
</tr>
<tr>
<td width="304">Max. PV Input Voltage (V)</td>
<td colspan="5" width="840">800</td>
</tr>
<tr>
<td width="304">Start-up Voltage (V)</td>
<td colspan="5" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT Voltage Range (V)</td>
<td colspan="5" width="840">200-650</td>
</tr>
<tr>
<td width="304">Rated PV Input Voltage (V)</td>
<td colspan="5" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="840">20+20</td>
</tr>
<tr>
<td width="304">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="840">30+30</td>
</tr>
<tr>
<td width="304">No. of MPP Trackers/No. of Strings MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
</tr>
<tr>
<td width="304">AC Input/Output Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Active Power (W)</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Apparent Power (VA)</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Current (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Current (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
</tr>
<tr>
<td width="304">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="840">45</td>
</tr>
<tr>
<td width="304">Peak Power (off-grid) (W)</td>
<td colspan="5" width="840">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="304">Power Factor Adjustment Range</td>
<td colspan="5" width="840">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="304">Rated Input/Output Voltage</td>
<td colspan="5" width="840">220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE</td>
</tr>
<tr>
<td width="304">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="840">&lt;3% (of nominal power)</td>
</tr>
<tr>
<td width="304">DC Injection Current</td>
<td colspan="5" width="840">&lt;0.5% In</td>
</tr>
<tr>
<td colspan="6" width="1144">Eﬃciency</td>
</tr>
<tr>
<td width="304">Max. Efﬁciency</td>
<td colspan="5" width="840">97.6%</td>
</tr>
<tr>
<td width="304">Euro Efﬁciency</td>
<td colspan="5" width="840">97.0%</td>
</tr>
<tr>
<td width="304">MPPT Efﬁciency</td>
<td colspan="5" width="840">&gt;99%</td>
</tr>
<tr>
<td colspan="6" width="1144">Equipment Protection</td>
</tr>
<tr>
<td width="304">Integrated</td>
<td colspan="5" width="840">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</div>
</td>
</tr>
<tr>
<td width="304">Surge Protection Level</td>
<td colspan="5" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td colspan="6" width="1144">Interface</td>
</tr>
<tr>
<td width="304">LCD/LED Display</td>
<td colspan="5" width="840">LCD</td>
</tr>
<tr>
<td width="304">Communication Interface</td>
<td colspan="5" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td colspan="6" width="1144">General Data</td>
</tr>
<tr>
<td width="304">Operating Temperature Range (℃)</td>
<td colspan="5" width="840">-40 to +60℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="304">Permissible Ambient Humidity</td>
<td colspan="5" width="840">0-100%</td>
</tr>
<tr>
<td width="304">Permissible Altitude</td>
<td colspan="5" width="840">3000m</td>
</tr>
<tr>
<td width="304">Noise (dB)</td>
<td colspan="5" width="840">≤45</td>
</tr>
<tr>
<td width="304">Ingress Protection(IP) Rating</td>
<td colspan="5" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Inverter Topology</td>
<td colspan="5" width="840">Non-Isolated (solar), Isolated (battery)</td>
</tr>
<tr>
<td width="304">Over Voltage Category</td>
<td colspan="5" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="840">334×545×220 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="304">Weight (kg)</td>
<td colspan="4" width="840">20.8</td>
<td>21.9</td>
</tr>
<tr>
<td width="304">Type of Cooling</td>
<td colspan="5" width="840">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="304">Warranty</td>
<td colspan="5" width="840">5 Years/10 Years<br />
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="304">Grid Regulation</td>
<td colspan="5" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Safety / EMC Standard</td>
<td colspan="5" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-6K-SG06LP1-EU-BM2</title>
		<link>https://inverter.at/product/sun-6k-sg06lp1-eu-bm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:45 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=668</guid>

					<description><![CDATA[<ul>
 	<li>48V low voltage battery, transformer isolation design</li>
 	<li>AC couple to retrofit existing solar system</li>
 	<li>Max. 10 pcs parallel for on-grid and off-grid operation; support multiple batteries parallel</li>
 	<li>6 time periods for battery charging/discharging</li>
 	<li>Max. charging/discharging current of 190A</li>
 	<li>Support storing energy from diesel generator</li>
 	<li>100% unbalanced output, max. output up to 50% rated power for each phase</li>
</ul>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Model</td>
<td width="120">SUN-3K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-4K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-5K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-6K-SG06<br />
LP3-EU-BM2</td>
<td width="120">SUN-8K-SG06<br />
LP3-EU-BM2</td>
</tr>
<tr>
<td width="304">Battery Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Battery Type</td>
<td colspan="5" width="840">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="304">Battery Voltage Range (V)</td>
<td colspan="5" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Charging/Discharging Current (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
</tr>
<tr>
<td width="304">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="840">Self-adaption to BMS</td>
</tr>
<tr>
<td width="304">Number of Battery Input</td>
<td colspan="5" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Input Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
</tr>
<tr>
<td width="304">Max. PV Input Power (W)</td>
<td width="120">4800</td>
<td width="120">6400</td>
<td width="120">8000</td>
<td width="120">9600</td>
<td width="120">12800</td>
</tr>
<tr>
<td width="304">Max. PV Input Voltage (V)</td>
<td colspan="5" width="840">800</td>
</tr>
<tr>
<td width="304">Start-up Voltage (V)</td>
<td colspan="5" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT Voltage Range (V)</td>
<td colspan="5" width="840">200-650</td>
</tr>
<tr>
<td width="304">Rated PV Input Voltage (V)</td>
<td colspan="5" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="840">20+20</td>
</tr>
<tr>
<td width="304">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="840">30+30</td>
</tr>
<tr>
<td width="304">No. of MPP Trackers/No. of Strings MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
</tr>
<tr>
<td width="304">AC Input/Output Data</td>
<td colspan="5" width="840"></td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Active Power (W)</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Apparent Power (VA)</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
</tr>
<tr>
<td width="304">Rated AC Input/Output Current (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
</tr>
<tr>
<td width="304">Max. AC Input/Output Current (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
</tr>
<tr>
<td width="304">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="840">45</td>
</tr>
<tr>
<td width="304">Peak Power (off-grid) (W)</td>
<td colspan="5" width="840">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="304">Power Factor Adjustment Range</td>
<td colspan="5" width="840">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="304">Rated Input/Output Voltage</td>
<td colspan="5" width="840">220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE</td>
</tr>
<tr>
<td width="304">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="840">&lt;3% (of nominal power)</td>
</tr>
<tr>
<td width="304">DC Injection Current</td>
<td colspan="5" width="840">&lt;0.5% In</td>
</tr>
<tr>
<td colspan="6" width="1144">Eﬃciency</td>
</tr>
<tr>
<td width="304">Max. Efﬁciency</td>
<td colspan="5" width="840">97.6%</td>
</tr>
<tr>
<td width="304">Euro Efﬁciency</td>
<td colspan="5" width="840">97.0%</td>
</tr>
<tr>
<td width="304">MPPT Efﬁciency</td>
<td colspan="5" width="840">&gt;99%</td>
</tr>
<tr>
<td colspan="6" width="1144">Equipment Protection</td>
</tr>
<tr>
<td width="304">Integrated</td>
<td colspan="5" width="840">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</div>
</td>
</tr>
<tr>
<td width="304">Surge Protection Level</td>
<td colspan="5" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td colspan="6" width="1144">Interface</td>
</tr>
<tr>
<td width="304">LCD/LED Display</td>
<td colspan="5" width="840">LCD</td>
</tr>
<tr>
<td width="304">Communication Interface</td>
<td colspan="5" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td colspan="6" width="1144">General Data</td>
</tr>
<tr>
<td width="304">Operating Temperature Range (℃)</td>
<td colspan="5" width="840">-40 to +60℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="304">Permissible Ambient Humidity</td>
<td colspan="5" width="840">0-100%</td>
</tr>
<tr>
<td width="304">Permissible Altitude</td>
<td colspan="5" width="840">3000m</td>
</tr>
<tr>
<td width="304">Noise (dB)</td>
<td colspan="5" width="840">≤45</td>
</tr>
<tr>
<td width="304">Ingress Protection(IP) Rating</td>
<td colspan="5" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Inverter Topology</td>
<td colspan="5" width="840">Non-Isolated (solar), Isolated (battery)</td>
</tr>
<tr>
<td width="304">Over Voltage Category</td>
<td colspan="5" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="840">334×545×220 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="304">Weight (kg)</td>
<td colspan="4" width="840">20.8</td>
<td>21.9</td>
</tr>
<tr>
<td width="304">Type of Cooling</td>
<td colspan="5" width="840">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="304">Warranty</td>
<td colspan="5" width="840">5 Years/10 Years<br />
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="304">Grid Regulation</td>
<td colspan="5" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Safety / EMC Standard</td>
<td colspan="5" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-10K-SG05LP3-EU-SM2</title>
		<link>https://inverter.at/product/sun-10k-sg05lp3-eu-sm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:44 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=659</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100% unsymmetrische Ausgang: jede Phase max.</div>
<div>Ausgang ist bis zu 50% der Nennleistung</div></li>
 	<li>
<div>AC-Koppel zur Nachrüstung bestehender Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (für On-Grid und Off-Grid Betrieb) Unterstützt mehrere Batterien parallel</div></li>
</ul>
<div>
<ul>
 	<li>
<div>Max. Lade-/Entladestrom von 240A</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung aus Dieselgenerator</div></li>
 	<li>
<div>48V Niedervoltbatterie, Transformator-Isolationsdesign</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
</ul>
</div>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Modelo</td>
<td width="120">SUN-3K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-4K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-5K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-6K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-8K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-10K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-12K-SG05<br />
LP3-EU-SM2</td>
</tr>
<tr>
<td width="304">BatterieEingangsdaten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Batterie-Typ</td>
<td colspan="7" width="840">Bleisäure oder Li-lon</td>
</tr>
<tr>
<td width="304">Batteriespannungsbereich (V)</td>
<td colspan="7" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Ladestrom (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
<td width="120">210</td>
<td width="120">240</td>
</tr>
<tr>
<td width="304">Max. Entladestrom (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
<td width="120">210</td>
<td width="120">240</td>
</tr>
<tr>
<td width="304">Ladestrategie für Li-Ionen-Batterie</td>
<td colspan="7" width="840">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="304">Anzahlder Batterieeingänge</td>
<td colspan="7" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Eingangsdaten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
</tr>
<tr>
<td width="304">Max.DC-Eingangsleistung (W)</td>
<td width="120">4500</td>
<td width="120">6400</td>
<td width="120">7500</td>
<td width="120">9600</td>
<td width="120">12800</td>
<td width="120">16000</td>
<td width="120">19200</td>
</tr>
<tr>
<td width="304">Max.DC-Eingangsspannung (V)</td>
<td colspan="7" width="840">800</td>
</tr>
<tr>
<td width="304">Startspannung (V)</td>
<td colspan="7" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT-Spannungsbereich (V)</td>
<td colspan="7" width="840">200-650</td>
</tr>
<tr>
<td width="304">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="5" width="840">20+20</td>
<td colspan="2">26+26</td>
</tr>
<tr>
<td width="304">Max. Eingangs-Kurzschlussstrom (A)</td>
<td colspan="5" width="840">30+30</td>
<td colspan="2">39+39</td>
</tr>
<tr>
<td width="304">Anzahlder MPP Trackers/<br />
Anzahlder Strings  MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
<td colspan="2">2/2+2</td>
</tr>
<tr>
<td width="304">AC-Eingang/Ausgangsseite</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Nenn-AC-Eingangs-/Ausgangswirkleistung</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
<td width="120">10000</td>
<td width="120">12000</td>
</tr>
<tr>
<td width="304">Max. AC-Eingangs-/Ausgangs-Scheinleistung</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
<td width="120">11000</td>
<td width="120">13200</td>
</tr>
<tr>
<td width="304">AC-Eingangs-/Ausgangsnennstrom (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
<td width="120">15.2/14.5</td>
<td width="120">18.2/17.4</td>
</tr>
<tr>
<td width="304">Max. AC-Eingangs-/Ausgangssstrom (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
<td width="120">16.7/16</td>
<td width="120">20/19.2</td>
</tr>
<tr>
<td width="304">Max. KontinuierlicherAC-Passthrough (Netz zum Laden)</td>
<td colspan="7" width="840">45</td>
</tr>
<tr>
<td width="304">Spitzenleistung (ohne Netz)</td>
<td colspan="7" width="840">2fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="304">Einstellbereich des Leistungsfaktors</td>
<td colspan="7" width="840">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="304">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="7" width="840">220/380V, 230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="304">Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</td>
<td colspan="7" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Form des Netzanschlusses</td>
<td colspan="7" width="840">3L+N+PE</td>
</tr>
<tr>
<td width="304">Gesamte harmonischeStromverzerrung (THDi)</td>
<td colspan="7" width="840">&lt;3% ( Nennleistung )</td>
</tr>
<tr>
<td width="304">DC-strom stromeinspeisung</td>
<td colspan="7" width="840">&lt;0,5% In</td>
</tr>
<tr>
<td width="304">Wirkungsgrad</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Max.Wirkungsgrad</td>
<td colspan="7" width="840">97,6%</td>
</tr>
<tr>
<td width="304">Euro-Wirkungsgrad</td>
<td colspan="7" width="840">97,0%</td>
</tr>
<tr>
<td width="304">MPPT-Wirkungsgrad</td>
<td colspan="7" width="840">&gt;99%</td>
</tr>
<tr>
<td width="304">Schutz derGeräte</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Integriert</td>
<td colspan="7" width="840">
<div>DC-Verpolungsschutz, AC-Ausgang-Überstromschutz, AC-Ausgang-Überspannungsschutz, AC-Ausgang-Kurzschlussschutz, Temperaturschutz, Erkennung der Isolationsimpedanz, DC-Komponenten-Überwachung, Störlichtbogen-Schutzschalter (AFCI)(optional), Inselbildungsschutz (Anti-Islanding),DC-Schalter, Fehlerstromerkennung</div>
</td>
</tr>
<tr>
<td width="304">Überspannungs schutzstufe</td>
<td colspan="7" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="304">Schnittstelle</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Kommunikationsschnittstelle</td>
<td colspan="7" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td width="304">LCD/LED-Anzeige</td>
<td colspan="7" width="840">LCD</td>
</tr>
<tr>
<td width="304">Allgemeine Daten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Betriebstemperaturbereich (°C)</td>
<td colspan="7" width="840">-40 to +60℃, &gt;45℃  Leistungsminderung</td>
</tr>
<tr>
<td width="304">ZulässigeUmgebungsfeuchte</td>
<td colspan="7" width="840">0-100%</td>
</tr>
<tr>
<td width="304">ZulässigeHöhenlage</td>
<td colspan="7" width="840">2000m</td>
</tr>
<tr>
<td width="304">Lärm (dB)</td>
<td colspan="7" width="840">&lt;55 dB(A)</td>
</tr>
<tr>
<td width="304">Schutzart</td>
<td colspan="7" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Wechselrichter-Topologie</td>
<td colspan="7" width="840">Nicht-isoliert</td>
</tr>
<tr>
<td width="304">Überspannungskategorie</td>
<td colspan="7" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Abmessung (BxHxT mm)</td>
<td colspan="7" width="840">386×660×250  (Ohne Steckverbinder und Halterungen）</td>
</tr>
<tr>
<td width="304">Gewicht (kg)</td>
<td colspan="7" width="840">35.2</td>
</tr>
<tr>
<td width="304">Kühlmodus</td>
<td colspan="7" width="840">IntelligenteKühlung</td>
</tr>
<tr>
<td width="304">Garantie</td>
<td colspan="7" width="840">5-jährige/10-jährige Garantiezeit hängt von den<br />
Installationsbedingungendes Wechselrichtersab. Einzelheiten ﬁnden Sie in den allgemeinenGarantiebedingungen</td>
</tr>
<tr>
<td width="304">Netzregelung</td>
<td colspan="7" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25, G98,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Sicherheit EMC / Standard</td>
<td colspan="7" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-8K-SG05LP3-EU-SM2</title>
		<link>https://inverter.at/product/sun-8k-sg05lp3-eu-sm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:44 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=660</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100% unsymmetrische Ausgang: jede Phase max.</div>
<div>Ausgang ist bis zu 50% der Nennleistung</div></li>
 	<li>
<div>AC-Koppel zur Nachrüstung bestehender Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (für On-Grid und Off-Grid Betrieb) Unterstützt mehrere Batterien parallel</div></li>
</ul>
<div>
<ul>
 	<li>
<div>Max. Lade-/Entladestrom von 240A</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung aus Dieselgenerator</div></li>
 	<li>
<div>48V Niedervoltbatterie, Transformator-Isolationsdesign</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
</ul>
</div>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Modelo</td>
<td width="120">SUN-3K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-4K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-5K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-6K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-8K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-10K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-12K-SG05<br />
LP3-EU-SM2</td>
</tr>
<tr>
<td width="304">BatterieEingangsdaten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Batterie-Typ</td>
<td colspan="7" width="840">Bleisäure oder Li-lon</td>
</tr>
<tr>
<td width="304">Batteriespannungsbereich (V)</td>
<td colspan="7" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Ladestrom (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
<td width="120">210</td>
<td width="120">240</td>
</tr>
<tr>
<td width="304">Max. Entladestrom (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
<td width="120">210</td>
<td width="120">240</td>
</tr>
<tr>
<td width="304">Ladestrategie für Li-Ionen-Batterie</td>
<td colspan="7" width="840">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="304">Anzahlder Batterieeingänge</td>
<td colspan="7" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Eingangsdaten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
</tr>
<tr>
<td width="304">Max.DC-Eingangsleistung (W)</td>
<td width="120">4500</td>
<td width="120">6400</td>
<td width="120">7500</td>
<td width="120">9600</td>
<td width="120">12800</td>
<td width="120">16000</td>
<td width="120">19200</td>
</tr>
<tr>
<td width="304">Max.DC-Eingangsspannung (V)</td>
<td colspan="7" width="840">800</td>
</tr>
<tr>
<td width="304">Startspannung (V)</td>
<td colspan="7" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT-Spannungsbereich (V)</td>
<td colspan="7" width="840">200-650</td>
</tr>
<tr>
<td width="304">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="5" width="840">20+20</td>
<td colspan="2">26+26</td>
</tr>
<tr>
<td width="304">Max. Eingangs-Kurzschlussstrom (A)</td>
<td colspan="5" width="840">30+30</td>
<td colspan="2">39+39</td>
</tr>
<tr>
<td width="304">Anzahlder MPP Trackers/<br />
Anzahlder Strings  MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
<td colspan="2">2/2+2</td>
</tr>
<tr>
<td width="304">AC-Eingang/Ausgangsseite</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Nenn-AC-Eingangs-/Ausgangswirkleistung</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
<td width="120">10000</td>
<td width="120">12000</td>
</tr>
<tr>
<td width="304">Max. AC-Eingangs-/Ausgangs-Scheinleistung</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
<td width="120">11000</td>
<td width="120">13200</td>
</tr>
<tr>
<td width="304">AC-Eingangs-/Ausgangsnennstrom (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
<td width="120">15.2/14.5</td>
<td width="120">18.2/17.4</td>
</tr>
<tr>
<td width="304">Max. AC-Eingangs-/Ausgangssstrom (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
<td width="120">16.7/16</td>
<td width="120">20/19.2</td>
</tr>
<tr>
<td width="304">Max. KontinuierlicherAC-Passthrough (Netz zum Laden)</td>
<td colspan="7" width="840">45</td>
</tr>
<tr>
<td width="304">Spitzenleistung (ohne Netz)</td>
<td colspan="7" width="840">2fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="304">Einstellbereich des Leistungsfaktors</td>
<td colspan="7" width="840">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="304">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="7" width="840">220/380V, 230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="304">Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</td>
<td colspan="7" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Form des Netzanschlusses</td>
<td colspan="7" width="840">3L+N+PE</td>
</tr>
<tr>
<td width="304">Gesamte harmonischeStromverzerrung (THDi)</td>
<td colspan="7" width="840">&lt;3% ( Nennleistung )</td>
</tr>
<tr>
<td width="304">DC-strom stromeinspeisung</td>
<td colspan="7" width="840">&lt;0,5% In</td>
</tr>
<tr>
<td width="304">Wirkungsgrad</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Max.Wirkungsgrad</td>
<td colspan="7" width="840">97,6%</td>
</tr>
<tr>
<td width="304">Euro-Wirkungsgrad</td>
<td colspan="7" width="840">97,0%</td>
</tr>
<tr>
<td width="304">MPPT-Wirkungsgrad</td>
<td colspan="7" width="840">&gt;99%</td>
</tr>
<tr>
<td width="304">Schutz derGeräte</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Integriert</td>
<td colspan="7" width="840">
<div>DC-Verpolungsschutz, AC-Ausgang-Überstromschutz, AC-Ausgang-Überspannungsschutz, AC-Ausgang-Kurzschlussschutz, Temperaturschutz, Erkennung der Isolationsimpedanz, DC-Komponenten-Überwachung, Störlichtbogen-Schutzschalter (AFCI)(optional), Inselbildungsschutz (Anti-Islanding),DC-Schalter, Fehlerstromerkennung</div>
</td>
</tr>
<tr>
<td width="304">Überspannungs schutzstufe</td>
<td colspan="7" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="304">Schnittstelle</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Kommunikationsschnittstelle</td>
<td colspan="7" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td width="304">LCD/LED-Anzeige</td>
<td colspan="7" width="840">LCD</td>
</tr>
<tr>
<td width="304">Allgemeine Daten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Betriebstemperaturbereich (°C)</td>
<td colspan="7" width="840">-40 to +60℃, &gt;45℃  Leistungsminderung</td>
</tr>
<tr>
<td width="304">ZulässigeUmgebungsfeuchte</td>
<td colspan="7" width="840">0-100%</td>
</tr>
<tr>
<td width="304">ZulässigeHöhenlage</td>
<td colspan="7" width="840">2000m</td>
</tr>
<tr>
<td width="304">Lärm (dB)</td>
<td colspan="7" width="840">&lt;55 dB(A)</td>
</tr>
<tr>
<td width="304">Schutzart</td>
<td colspan="7" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Wechselrichter-Topologie</td>
<td colspan="7" width="840">Nicht-isoliert</td>
</tr>
<tr>
<td width="304">Überspannungskategorie</td>
<td colspan="7" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Abmessung (BxHxT mm)</td>
<td colspan="7" width="840">386×660×250  (Ohne Steckverbinder und Halterungen）</td>
</tr>
<tr>
<td width="304">Gewicht (kg)</td>
<td colspan="7" width="840">35.2</td>
</tr>
<tr>
<td width="304">Kühlmodus</td>
<td colspan="7" width="840">IntelligenteKühlung</td>
</tr>
<tr>
<td width="304">Garantie</td>
<td colspan="7" width="840">5-jährige/10-jährige Garantiezeit hängt von den<br />
Installationsbedingungendes Wechselrichtersab. Einzelheiten ﬁnden Sie in den allgemeinenGarantiebedingungen</td>
</tr>
<tr>
<td width="304">Netzregelung</td>
<td colspan="7" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25, G98,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Sicherheit EMC / Standard</td>
<td colspan="7" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-6K-SG05LP3-EU-SM2</title>
		<link>https://inverter.at/product/sun-6k-sg05lp3-eu-sm2/</link>
		
		<dc:creator><![CDATA[admin_deyeAT]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 21:29:44 +0000</pubDate>
				<guid isPermaLink="false">https://inverter.at/?post_type=product&#038;p=661</guid>

					<description><![CDATA[<ul>
 	<li>
<div>100% unsymmetrische Ausgang: jede Phase max.</div>
<div>Ausgang ist bis zu 50% der Nennleistung</div></li>
 	<li>
<div>AC-Koppel zur Nachrüstung bestehender Solaranlage</div></li>
 	<li>
<div>Max. 10 Einheiten parallel (für On-Grid und Off-Grid Betrieb) Unterstützt mehrere Batterien parallel</div></li>
</ul>
<div>
<ul>
 	<li>
<div>Max. Lade-/Entladestrom von 240A</div></li>
 	<li>
<div>Unterstützt die Energiespeicherung aus Dieselgenerator</div></li>
 	<li>
<div>48V Niedervoltbatterie, Transformator-Isolationsdesign</div></li>
 	<li>
<div>6 einstellbare Zeiträume zum Laden und Entladen der Batterie</div></li>
</ul>
</div>]]></description>
										<content:encoded><![CDATA[<table>
<tbody>
<tr>
<td width="304">Modelo</td>
<td width="120">SUN-3K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-4K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-5K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-6K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-8K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-10K-SG05<br />
LP3-EU-SM2</td>
<td width="120">SUN-12K-SG05<br />
LP3-EU-SM2</td>
</tr>
<tr>
<td width="304">BatterieEingangsdaten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Batterie-Typ</td>
<td colspan="7" width="840">Bleisäure oder Li-lon</td>
</tr>
<tr>
<td width="304">Batteriespannungsbereich (V)</td>
<td colspan="7" width="840">40-60</td>
</tr>
<tr>
<td width="304">Max. Ladestrom (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
<td width="120">210</td>
<td width="120">240</td>
</tr>
<tr>
<td width="304">Max. Entladestrom (A)</td>
<td width="120">70</td>
<td width="120">95</td>
<td width="120">120</td>
<td width="120">135</td>
<td width="120">190</td>
<td width="120">210</td>
<td width="120">240</td>
</tr>
<tr>
<td width="304">Ladestrategie für Li-Ionen-Batterie</td>
<td colspan="7" width="840">Selbstanpassung an BMS</td>
</tr>
<tr>
<td width="304">Anzahlder Batterieeingänge</td>
<td colspan="7" width="840">1</td>
</tr>
<tr>
<td width="304">PV String Eingangsdaten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div>
</td>
<td>6000</td>
<td>8000</td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
</tr>
<tr>
<td width="304">Max.DC-Eingangsleistung (W)</td>
<td width="120">4500</td>
<td width="120">6400</td>
<td width="120">7500</td>
<td width="120">9600</td>
<td width="120">12800</td>
<td width="120">16000</td>
<td width="120">19200</td>
</tr>
<tr>
<td width="304">Max.DC-Eingangsspannung (V)</td>
<td colspan="7" width="840">800</td>
</tr>
<tr>
<td width="304">Startspannung (V)</td>
<td colspan="7" width="840">160</td>
</tr>
<tr>
<td width="304">MPPT-Spannungsbereich (V)</td>
<td colspan="7" width="840">200-650</td>
</tr>
<tr>
<td width="304">Nenn-DC-Eingangsspannung (V)</td>
<td colspan="7" width="840">550</td>
</tr>
<tr>
<td width="304">Max. Betriebs-PV-Eingangsstrom (A)</td>
<td colspan="5" width="840">20+20</td>
<td colspan="2">26+26</td>
</tr>
<tr>
<td width="304">Max. Eingangs-Kurzschlussstrom (A)</td>
<td colspan="5" width="840">30+30</td>
<td colspan="2">39+39</td>
</tr>
<tr>
<td width="304">Anzahlder MPP Trackers/<br />
Anzahlder Strings  MPP Tracker</td>
<td colspan="5" width="840">2/1+1</td>
<td colspan="2">2/2+2</td>
</tr>
<tr>
<td width="304">AC-Eingang/Ausgangsseite</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Nenn-AC-Eingangs-/Ausgangswirkleistung</td>
<td width="120">3000</td>
<td width="120">4000</td>
<td width="120">5000</td>
<td width="120">6000</td>
<td width="120">8000</td>
<td width="120">10000</td>
<td width="120">12000</td>
</tr>
<tr>
<td width="304">Max. AC-Eingangs-/Ausgangs-Scheinleistung</td>
<td width="120">3300</td>
<td width="120">4400</td>
<td width="120">5500</td>
<td width="120">6600</td>
<td width="120">8800</td>
<td width="120">11000</td>
<td width="120">13200</td>
</tr>
<tr>
<td width="304">AC-Eingangs-/Ausgangsnennstrom (A)</td>
<td width="120">4.6/4.4</td>
<td width="120">6.1/5.8</td>
<td width="120">7.6/7.3</td>
<td width="120">9.1/8.7</td>
<td width="120">12.2/11.6</td>
<td width="120">15.2/14.5</td>
<td width="120">18.2/17.4</td>
</tr>
<tr>
<td width="304">Max. AC-Eingangs-/Ausgangssstrom (A)</td>
<td width="120">5/4.8</td>
<td width="120">6.7/6.4</td>
<td width="120">8.4/8</td>
<td width="120">10/9.6</td>
<td width="120">13.4/12.8</td>
<td width="120">16.7/16</td>
<td width="120">20/19.2</td>
</tr>
<tr>
<td width="304">Max. KontinuierlicherAC-Passthrough (Netz zum Laden)</td>
<td colspan="7" width="840">45</td>
</tr>
<tr>
<td width="304">Spitzenleistung (ohne Netz)</td>
<td colspan="7" width="840">2fache Nennausgangsleistung, 10s</td>
</tr>
<tr>
<td width="304">Einstellbereich des Leistungsfaktors</td>
<td colspan="7" width="840">0,8 führend bis 0,8 nachlaufend</td>
</tr>
<tr>
<td width="304">Nenn-Eingangs-/Ausgangsspannung/Bereich (V)</td>
<td colspan="7" width="840">220/380V, 230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="304">Nenn-Eingangs-/Ausgangsnetzfrequenz/Bereich (Hz)</td>
<td colspan="7" width="840">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="304">Form des Netzanschlusses</td>
<td colspan="7" width="840">3L+N+PE</td>
</tr>
<tr>
<td width="304">Gesamte harmonischeStromverzerrung (THDi)</td>
<td colspan="7" width="840">&lt;3% ( Nennleistung )</td>
</tr>
<tr>
<td width="304">DC-strom stromeinspeisung</td>
<td colspan="7" width="840">&lt;0,5% In</td>
</tr>
<tr>
<td width="304">Wirkungsgrad</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Max.Wirkungsgrad</td>
<td colspan="7" width="840">97,6%</td>
</tr>
<tr>
<td width="304">Euro-Wirkungsgrad</td>
<td colspan="7" width="840">97,0%</td>
</tr>
<tr>
<td width="304">MPPT-Wirkungsgrad</td>
<td colspan="7" width="840">&gt;99%</td>
</tr>
<tr>
<td width="304">Schutz derGeräte</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Integriert</td>
<td colspan="7" width="840">
<div>DC-Verpolungsschutz, AC-Ausgang-Überstromschutz, AC-Ausgang-Überspannungsschutz, AC-Ausgang-Kurzschlussschutz, Temperaturschutz, Erkennung der Isolationsimpedanz, DC-Komponenten-Überwachung, Störlichtbogen-Schutzschalter (AFCI)(optional), Inselbildungsschutz (Anti-Islanding),DC-Schalter, Fehlerstromerkennung</div>
</td>
</tr>
<tr>
<td width="304">Überspannungs schutzstufe</td>
<td colspan="7" width="840">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="304">Schnittstelle</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Kommunikationsschnittstelle</td>
<td colspan="7" width="840">WIFI,RS485,CAN</td>
</tr>
<tr>
<td width="304">LCD/LED-Anzeige</td>
<td colspan="7" width="840">LCD</td>
</tr>
<tr>
<td width="304">Allgemeine Daten</td>
<td colspan="7" width="840"></td>
</tr>
<tr>
<td width="304">Betriebstemperaturbereich (°C)</td>
<td colspan="7" width="840">-40 to +60℃, &gt;45℃  Leistungsminderung</td>
</tr>
<tr>
<td width="304">ZulässigeUmgebungsfeuchte</td>
<td colspan="7" width="840">0-100%</td>
</tr>
<tr>
<td width="304">ZulässigeHöhenlage</td>
<td colspan="7" width="840">2000m</td>
</tr>
<tr>
<td width="304">Lärm (dB)</td>
<td colspan="7" width="840">&lt;55 dB(A)</td>
</tr>
<tr>
<td width="304">Schutzart</td>
<td colspan="7" width="840">IP 65</td>
</tr>
<tr>
<td width="304">Wechselrichter-Topologie</td>
<td colspan="7" width="840">Nicht-isoliert</td>
</tr>
<tr>
<td width="304">Überspannungskategorie</td>
<td colspan="7" width="840">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="304">Abmessung (BxHxT mm)</td>
<td colspan="7" width="840">386×660×250  (Ohne Steckverbinder und Halterungen）</td>
</tr>
<tr>
<td width="304">Gewicht (kg)</td>
<td colspan="7" width="840">35.2</td>
</tr>
<tr>
<td width="304">Kühlmodus</td>
<td colspan="7" width="840">IntelligenteKühlung</td>
</tr>
<tr>
<td width="304">Garantie</td>
<td colspan="7" width="840">5-jährige/10-jährige Garantiezeit hängt von den<br />
Installationsbedingungendes Wechselrichtersab. Einzelheiten ﬁnden Sie in den allgemeinenGarantiebedingungen</td>
</tr>
<tr>
<td width="304">Netzregelung</td>
<td colspan="7" width="840">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,<br />
OVE-Richtlinie R25, G98,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="304">Sicherheit EMC / Standard</td>
<td colspan="7" width="840">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>